RO A2 Series Reverse Osmosis Systems

At the core of the reverse osmosis purification system are semi-permeable membranes. When high-pressure water is supplied to the membrane, only pure water molecules and about 1-3% of the solutes in the water can pass through the membrane pores. Thus, microorganisms such as bacteria and viruses are filtered out.

RO A2 Series Reverse Osmosis Systems

At the core of the reverse osmosis purification system are semi-permeable membranes. The semi-permeable pore structure on these membranes is larger than the molecular size of pure water but smaller than the molecular sizes of dissolved substances in water. When high-pressure water is supplied to the membrane, only pure water molecules and about 1-3% of the solutes in the water can penetrate through the membrane pores. Thus, while dissolved substances in the water are retained by a minimum of 98% depending on their sizes, suspended solid particles, bacteria, and viruses are filtered out.

System Features:

  • Capacity: 1 m³/day – 90 m³/day
  • Membrane Housings: FRP or Stainless Steel
  • TFC Spiral Wound Membranes with 2.5” and 4” diameters
  • 304 quality stainless steel vertical centrifugal high-pressure pump
  • Brass body rotary type high-pressure pump
  • 304 quality stainless steel chassis
  • 5-micron cartridge filtration
  • Low and high-pressure pipes
  • Input solenoid valve on pump outlet and waste water line
  • Pressure adjustment needle valves
  • Low and high-pressure switches
  • Clean and waste water flow meters
  • Glycerin-filled pressure gauges
  • Product water conductivity indicator (0-2000µs/cm)
  • Autoflush system
  • On-Off switch
  • Alarm and status lights
  • 220 V/50Hz/3ph or 380 V/50Hz/3ph IP56 control panel

Recommended Inlet Water Limits:

  • Inlet Water TDS: 0-2,000 ppm
  • Operating Pressure: between 10 and 15 bar
  • Inlet Water Pressure: between 2 and 5 bar
  • If hardness is over 3 French, ASC dosing is required.
  • pH Range: 6-8
  • Silica (SiO2) Tolerance: 25 cm ppm Maximum @ 60% efficiency
  • Maximum Inlet Water Temperature: 30°C
  • Maximum Iron (Fe2+) Tolerance: 0.05 ppm, if ASC is dosed then 0.2 ppm
  • Hydrogen Sulfide should not be present.
  • There should be no turbidity (NTU 1).

RO B2 Series Reverse Osmosis Systems

SYSTEM FEATURES

Capacity: 40 m³/day – 120 m³/day Membrane Housings: FRP or Stainless Steel TFC Spiral Wound Membranes with 4” diameter Vertical centrifugal high-pressure pump made of 304 or 316 quality stainless steel Chassis made of St37 Epoxy painted Carbon Steel or AISI304 quality stainless steel 5-micron cartridge filtration Low-pressure line: U-PVC PN16 High-pressure line: AISI304 quality stainless steel Input solenoid valve or electric actuator butterfly valve on pump outlet and waste water line; pressure adjustment globe valves Low and high-pressure switches Clean and waste water flow meters Backflow meter (optional) Autoflush system On-Off switch Alarm and status lights 380 V/50Hz/3ph IP56 control panel

RECOMMENDED INLET WATER LIMITS

Inlet Water TDS: 0-2,000 ppm Operating Pressure: between 10 and 15 bar Inlet Water Pressure: between 2 and 5 If hardness is over 3 French, ASC dosing is required. pH Range: 6-8 Silica (SiO2) Tolerance: 25 ppm Maximum @ 60% efficiency Maximum Inlet Water Temperature: 30°C Maximum Iron (Fe2+) Tolerance: 0.05 ppm, if ASC is dosed then 0.2 ppm Hydrogen Sulfide should not be present. There should be no turbidity (NTU 1).

RO D41 Series Reverse Osmosis Systems

SYSTEM FEATURES

Membrane Housings: FRP TFC Spiral Wound Membranes with 8” diameter High-pressure pump made of St37 Epoxy painted Carbon Steel or AISI304 quality stainless steel Chassis made of St37 Epoxy painted Carbon Steel or AISI304 quality stainless steel 5-micron cartridge filtration Low-pressure line: U-PVC PN16 High-pressure line: AISI304 or Duplex Stainless Steel Input Electric actuator butterfly valve Low and high-pressure switches Clean and waste water flow meters Glycerin-filled pressure gauges Product water conductivity indicator (0-2000uS/cm) Input and product water pH meter (optional) On-Off switch Alarm and status lights 380 V/50Hz/3ph IP56 control panel

RECOMMENDED INLET WATER LIMITS

Inlet Water TDS: 38,000 – 41,000 ppm Operating Pressure: between 50 and 70 bar Inlet Water Pressure: between 2 and 5 bar pH Range: 6-8 Maximum Inlet Water Temperature: 30°C Hydrogen Sulfide should not be present. There should be no turbidity (NTU 1).